Sign In | Join Free | My burrillandco.com
Home > Solenoid Valve Coil >

1705244 1409391 Cylinder Cummins Engine Air-Assisted Dosing Urea Pump Electric Magnetic Coil

    Buy cheap 1705244 1409391 Cylinder Cummins Engine Air-Assisted Dosing Urea Pump Electric Magnetic Coil from wholesalers
     
    Buy cheap 1705244 1409391 Cylinder Cummins Engine Air-Assisted Dosing Urea Pump Electric Magnetic Coil from wholesalers
    • Buy cheap 1705244 1409391 Cylinder Cummins Engine Air-Assisted Dosing Urea Pump Electric Magnetic Coil from wholesalers
    • Buy cheap 1705244 1409391 Cylinder Cummins Engine Air-Assisted Dosing Urea Pump Electric Magnetic Coil from wholesalers
    • Buy cheap 1705244 1409391 Cylinder Cummins Engine Air-Assisted Dosing Urea Pump Electric Magnetic Coil from wholesalers
    • Buy cheap 1705244 1409391 Cylinder Cummins Engine Air-Assisted Dosing Urea Pump Electric Magnetic Coil from wholesalers
    • Buy cheap 1705244 1409391 Cylinder Cummins Engine Air-Assisted Dosing Urea Pump Electric Magnetic Coil from wholesalers

    1705244 1409391 Cylinder Cummins Engine Air-Assisted Dosing Urea Pump Electric Magnetic Coil

    Ask Lasest Price
    Brand Name : BRANDO
    Model Number : BB15036314
    Certification : None
    Payment Terms : T/T, PayPal, Western Union
    Supply Ability : 100000pcs per month
    Delivery Time : Negotiation
    Price : Negotiation
    • Product Details
    • Company Profile

    1705244 1409391 Cylinder Cummins Engine Air-Assisted Dosing Urea Pump Electric Magnetic Coil

    1705244 1409391 Cylinder Cummins Engine Air-Assisted Dosing Urea Pump electric magnetic coil ​

    This solenoid coil is widely used in automotive urea pumps like EMITEC Type Air-Assisted Urea Dosing Pump. The use of urea in vehicles is mainly to reduce harmful nitrogen oxides in the exhaust gas into nitrogen and water. Generally used in diesel vehicles. The harmful substances in the exhaust gas of diesel vehicles are mainly nitrogen oxides and particles. In the engine, the particulate emissions can be reduced by technical means, so that the exhaust gas is mainly nitrogen oxides, and the urea is injected into the exhaust gas after-treatment device, and the urea is decomposed at high temperature. For ammonia, it reacts with nitrogen oxides under the action of a catalyst to produce harmless nitrogen and water. This device is called an SCR aftertreatment system.

    What problems occur when the solenoid valve coil is in use?

    Everyone knows that solenoid valves play an important role in industrial applications, and they have a long running time, and sometimes there are some problems that make the equipment not function properly. Most of this problem is caused by improper use of the solenoid valve coil.

    The solenoid valve coil may not be very secure at the time of installation. During the operation of the device, the coil is in a strong operation, so that the coil will fall, the solenoid valve will not operate normally, or some may fall, and some may not. It may cause the device to work for a while and not work properly, both of which will delay the work. At this time, the operation is relatively simple, and the coil can be firmly fixed on the solenoid valve. There is also a case where the solenoid valve coil may be burnt out due to excessive voltage, and the device may not operate normally.

    Therefore, when using the solenoid valve later, be sure to check the position of the solenoid valve coil and do the correct operation of the solenoid valve coil. This will ensure that the solenoid valve will not cause problems.

    Dimension of BB15036314 Solenoid Valve Coil :

    Dimension of BB15036314 Solenoid Valve Coil :

    Technical Data:


    Model
    BB15036314
    Hole Size
    15.1mm
    Height
    33.2mm
    Width
    33mm
    Connector
    KOSTAL
    Insulation Class
    H
    Protection Class
    IP65, IP67, IP68
    Normal Voltage
    DC12V
    Power
    8W, 12W, 13.2W
    Application example
    Urea Doser Pump, Urea Solenoid Valve


    Solenoid Coil Production Line:


    Attention:
    1. This air suspension compressor pump solenoid coil is made of high quality components.

    2. Replaces the original air compressor solenoid coil of your car and equal the original quality.
    3. Please double confirm the compatibility as well as the OEM number before purchasing.
    4. Instruction is not included. Professional installation is recommended.


    Steps and methods for properly installing a solenoid valve coil:

    1. Check if the solenoid valve and the selected parameters are the same, such as differential pressure, etc. If the error occurs, the solenoid valve coil will be burned out. Voltage fluctuations should be within the normal range and meet the rated voltage.

    2. Before connecting the pipeline, flush the pipeline and remove the residual dirt in the pipeline. If there are residual stains, it will affect the normal use of the solenoid valve. To prevent this, a filter should be installed in the pipeline.

    3. Install the solenoid valve coil of the solenoid valve vertically on the horizontal and ground pipes. If there is a special situation, it cannot be installed vertically. The appropriate solenoid valve should be ordered in advance, otherwise the solenoid valve will not work properly.

    4. When installing, add a safety process and install a manual cutting valve to facilitate maintenance in case of failure.

    5. Pay attention to the direction when installing, can not be reversed, installed in the direction indicated on the package, and can be reversed in some special cases such as vacuum.

    6. If the water may be damaged by the medium, you must take appropriate protective measures or choose a solenoid valve with a waterproof hammer function.

    7. The solenoid valve cannot be energized all the time, otherwise it will reduce its life. Note that normally open, normally closed solenoid valves cannot be used with care.


    Product Features:
    1. Using high quality wire which has UL approved; 2. Using high quality permeablity magnetic material which contain low carbon;
    3. Using high quality housing material like PA66, PBT, PPS, BMC and so on.
    4. Insulation class can be B, F, H, N, C;
    5. Protection class can be IP65, IP67 & IP69K;
    6. We also offer special coils like ex-proof coils, water proof coils and so on.
    7. If you have special requirement, pls feel free to contact us.


    Focus on your demands, Offer you best solution:


    √ Contact us if some points you have doubt
    √ Contact us if somewhere need to change
    √ Contact us if not the one you are looking for
    √ Contact us if you are doing designing


    Welcome to your any question and inquiry!

    Quality 1705244 1409391 Cylinder Cummins Engine Air-Assisted Dosing Urea Pump Electric Magnetic Coil for sale
    Inquiry Cart 0
    Send your message to this supplier
     
    *From:
    *To: Ningbo Brando Hardware Co., Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)